Engineering records / Engineering record / ROOF-MASS-LEDGER-R1
Roof Mass Ledger R1.
Study overview
Geometry, analysis and remaining engineering work for Roof Mass Ledger R1.
Retained development study. Dimensions, names and checks belong to this revision—not automatically to the current retrofit system. Manufactured tanks are not offered. No installation instruction, certification or manufacturing release is represented.
The source reasoning
Why this detail was investigated.
The source reasoning
At the current 6 mm reinforcement allowance, the nine frame members contribute 44.29 kg and the six wraps 14.35 kg, using the source study's assumed 1560 kg/m³ density. The modeled bondline adds 0.90 kg at a separately assumed 1200 kg/m³.
Research record
The detail behind
the study.
Source-linked work for this revision. Reported checks describe the stated model or test; physical qualification and applicability to the current retrofit remain separate.
Read the research and limits
Roof-frame mass and clearance ledger
At the current 6 mm reinforcement allowance, the nine frame members contribute 44.29 kg and the six wraps 14.35 kg, using the source study's assumed 1560 kg/m³ density. The modeled bondline adds 0.90 kg at a separately assumed 1200 kg/m³.
The frame-plus-wrap subtotal is 129.26 lb, leaving only 3.04 lb in the old 132.3 lb allocation for the complete structure. This is insufficient evidence that the center support, rim, wall/base frames, partitions and hardpoints can fit that allocation. The former 451.9 lb whole-tank planning total cannot be carried forward as the current design's weight.
The finished conservative opening remains 931 × 547 mm before a collar, seal or closure. The 3 and 4.5 mm cases show sensitivity only; neither is a selected or strength-verified alternative. No thickness may be reduced solely to recover weight.
The ledger measures CAD solid volumes, not manufacturing waste or weighed parts. Resin-rich zones, corner fillets, ply transitions, skin, seats, hardware and protective layers are not silently included. Adhesive mass uses an estimating assumption pending material selection. This is a partial estimate, not a BOM or a complete tank mass claim.
Source and revision record
Source: roof-mass-ledger-r1/READ-ME.md
Source SHA-256: 1145a225ab974bd6ac3cc956f72afefa38f237755b9fb9b9b8d0eda26f1c7a71