Product family / Design study / PRODUCT-DESIGN-R1
The first family study.
The original tank, control, treatment and service product collection.
Retained development study. Dimensions, names and checks belong to this revision—not automatically to the retrofit-only product. Manufactured tank shells are deferred. No installation instruction, certification or manufacturing release is represented.

The source reasoning
Why this detail was investigated.
This earlier collection establishes the product relationships. Later component studies carry their own geometry and evidence; family imagery does not prove integration.
Read the research and limits

















Research record
The detail behind
the study.
Source-linked work for this revision. Reported checks describe the stated model or test; physical qualification and applicability to the current retrofit remain separate.
One
Formed lower vessel, Graphite roof and two access points. The Chalk shell carries the selected wordmark and split Fieldline on its front surface. Current 500 mm cover configuration. Process connections and structural release remain open.
Core
Chalk weather cover over a Graphite enclosure. The service view reveals a stationary interface faceplate above a separate power-compartment cover. 360 x 600 x 150 mm enclosure study. Supplier electronics, seals and attachment details remain open.
Tank Hub
A stationary carrier supports the removable housing independently of the tank lid. Twelve capped branch envelopes and numbered positions organize its service face. 310 x 410 x 115 mm packaging study. Electronics, contacts, cap retention and tank mounting remain open.
Alarm
A separate enclosure gives the alarm its own physical presence. A red optical insert is distinct from the orange brand stripe; the silence/test key stays visible. 150 x 230 x 65 mm enclosure study. Actual annunciators, detection logic and reserve power remain open.
Field Node
The enclosure repeats the family corner radii, cover seam and recessed working-surface color. Two closed entry envelopes sit below the identity band. 190 x 280 x 85 mm study. Field electronics, selected entries and site configuration remain open.
Adapter
A compact member of the same enclosure family, with a clear identity area and two closed connection envelopes. 95 x 180 x 58 mm study. Actual drivers, supplier interfaces and thermal design remain open.
Screen
The existing service assembly has a keyed head, pivoting retainer, cartridge support and capture sleeve. Its exploded view separates the actual CAD components. The supplied filter element, hydraulic isolation, sleeve actuation and seals remain open. Large support windows are not a filter cut size.
Field Filter
A cylindrical Chalk housing with two open pipe interfaces, a separate Graphite head and an internal element carrier. The logo follows the curved surface. Filter element, head retention, hydraulic isolation, bypass sealing and pressure qualification remain open.
Treat
Fixed guides remain while the wet carrier and cassette are removed. The restrained wordmark fits the existing front frame surface. The cassette is empty. Biological medium, distributor, collector and retention details remain open.
One / Inside
A CAD cutaway exposes the three chamber regions and retained structural frame. The included full tank STEP keeps all 2308 solids uncut. Partitions are currently closed. Transfer paths, actual equipment and final usable capacity remain open.
Access
The service adapter, riser and cover share controlled datums with the tank. Captive hardware and the secondary grate remain in the CAD assembly; the top wordmark clears the lift bores. The included access STEP also contains the pump-out branch. Whole-assembly qualification remains open.
Pump Dock
Hollow guide rails, sliding collars and a carrier frame form the retrieval study. Revised cradle clearances remove the rail clashes found in the assembly audit. Pump selection, hydraulic coupling, tank mounting, retention and lifting loads remain open.
Connect
One mechanical handling family with three different key orientations. Matching mechanical shells clear; mismatched class shells interfere in the geometry test. Contacts, locking, seals and electrical ratings are absent. This is a mechanical class-key study.
Sense Mount
An upright bracket provides instrument apertures and a replaceable metallic saddle. The identity sits on the solid upright, clear of the sensor openings. Exact supplier sensor geometry, clamping and installed location remain open.
Service Kit
A Chalk lid, Graphite body, separate latch envelopes and contacting handle brackets. The wordmark and Fieldline sit below the grip without being obscured. Tool layout, lining, hinge/latch engagement and attachment qualification remain open.
The complete product catalog.
All 48 shop entries are accounted for. Fourteen have a related partial concept render; remaining supplier and custom products need geometry. A housing render does not include an unseen PCB, motor, sensor, treatment medium or filter element.
| Product | Family | Model coverage |
|---|---|---|
| Subfield Core | Controllers | Partial concept |
| Tank Hub | Controllers | Partial concept |
| Field Node | Controllers | Partial concept |
| Equipment adapter | Controllers | Partial concept |
| Alarm assembly | Controllers | Partial concept |
| Exterior power module | Controllers | Model pending |
| Continuous level sensor | Sensors | Model pending |
| High-level detector | Sensors | Model pending |
| Low-level detector | Sensors | Model pending |
| Ponding detector | Sensors | Model pending |
| Flow instrument | Sensors | Model pending |
| Pressure instrument | Sensors | Model pending |
| Temperature probe | Sensors | Model pending |
| Filter seating indicator | Sensors | Model pending |
| Enclosure monitor | Sensors | Model pending |
| Soil observation probe | Sensors | Model pending |
| Treatment circulation pump | Pumps & treatment | Model pending |
| Reusable effluent screen | Pumps & treatment | Model pending |
| Screen housing | Pumps & treatment | Partial concept |
| Treatment media cassette | Pumps & treatment | Partial concept |
| Distribution manifold | Pumps & treatment | Model pending |
| Underdrain assembly | Pumps & treatment | Model pending |
| Recycle splitter | Pumps & treatment | Model pending |
| Sampling assembly | Pumps & treatment | Model pending |
| Hydraulic service kit | Pumps & treatment | Model pending |
| Power and data trunk | Cables & connections | Model pending |
| Device harness | Cables & connections | Model pending |
| Motor harness | Cables & connections | Model pending |
| Alarm and protective harness | Cables & connections | Model pending |
| Keyed connector set | Cables & connections | Partial concept |
| Cable entry and seal kit | Cables & connections | Model pending |
| Field harness | Cables & connections | Model pending |
| Service diagnostic lead | Cables & connections | Model pending |
| Subfield tank assembly | Tank & service | Partial concept |
| Service access and risers | Tank & service | Partial concept |
| Roof seal set | Tank & service | Model pending |
| Penetration interfaces | Tank & service | Model pending |
| Wet service carrier | Tank & service | Partial concept |
| Hub carrier and enclosure | Tank & service | Partial concept |
| Pump retrieval assembly | Tank & service | Partial concept |
| Level reference set | Tank & service | Model pending |
| Dispersal pump | Field equipment | Model pending |
| Pressure field filter | Field equipment | Partial concept |
| Zone and return valves | Field equipment | Model pending |
| Air-management kit | Field equipment | Model pending |
| Field piping and headers | Field equipment | Model pending |
| Wastewater dripline | Field equipment | Model pending |
| Flush-return flow instrument | Field equipment | Model pending |
Source and revision record
Source: product-design-r1/index-historical.html
Source SHA-256: 17dd953a3105e3bd9b8974c1a3d3b0481f5124ee5587e22d66dbf8c9e3c90339
Geometry and images describe this development revision. Current product ratings and manufacturing release require separate qualification.
Return to the current product.
Explore the retrofit-only platform and its compatibility, installation and service objectives.
Explore the retrofit