Skip to content
Back to the design archive

Product family / Design study / PRODUCT-DESIGN-R1

The first family study.

The original tank, control, treatment and service product collection.

Retained development study. Dimensions, names and checks belong to this revision—not automatically to the retrofit-only product. Manufactured tank shells are deferred. No installation instruction, certification or manufacturing release is represented.

One CAD concept, assembled
One CAD concept, assembled

The source reasoning

Why this detail was investigated.

This earlier collection establishes the product relationships. Later component studies carry their own geometry and evidence; family imagery does not prove integration.

Read the research and limits

Research record

The detail behind
the study.

Source-linked work for this revision. Reported checks describe the stated model or test; physical qualification and applicability to the current retrofit remain separate.

One

Formed lower vessel, Graphite roof and two access points. The Chalk shell carries the selected wordmark and split Fieldline on its front surface. Current 500 mm cover configuration. Process connections and structural release remain open.

Core

Chalk weather cover over a Graphite enclosure. The service view reveals a stationary interface faceplate above a separate power-compartment cover. 360 x 600 x 150 mm enclosure study. Supplier electronics, seals and attachment details remain open.

Tank Hub

A stationary carrier supports the removable housing independently of the tank lid. Twelve capped branch envelopes and numbered positions organize its service face. 310 x 410 x 115 mm packaging study. Electronics, contacts, cap retention and tank mounting remain open.

Alarm

A separate enclosure gives the alarm its own physical presence. A red optical insert is distinct from the orange brand stripe; the silence/test key stays visible. 150 x 230 x 65 mm enclosure study. Actual annunciators, detection logic and reserve power remain open.

Field Node

The enclosure repeats the family corner radii, cover seam and recessed working-surface color. Two closed entry envelopes sit below the identity band. 190 x 280 x 85 mm study. Field electronics, selected entries and site configuration remain open.

Adapter

A compact member of the same enclosure family, with a clear identity area and two closed connection envelopes. 95 x 180 x 58 mm study. Actual drivers, supplier interfaces and thermal design remain open.

Screen

The existing service assembly has a keyed head, pivoting retainer, cartridge support and capture sleeve. Its exploded view separates the actual CAD components. The supplied filter element, hydraulic isolation, sleeve actuation and seals remain open. Large support windows are not a filter cut size.

Field Filter

A cylindrical Chalk housing with two open pipe interfaces, a separate Graphite head and an internal element carrier. The logo follows the curved surface. Filter element, head retention, hydraulic isolation, bypass sealing and pressure qualification remain open.

Treat

Fixed guides remain while the wet carrier and cassette are removed. The restrained wordmark fits the existing front frame surface. The cassette is empty. Biological medium, distributor, collector and retention details remain open.

One / Inside

A CAD cutaway exposes the three chamber regions and retained structural frame. The included full tank STEP keeps all 2308 solids uncut. Partitions are currently closed. Transfer paths, actual equipment and final usable capacity remain open.

Access

The service adapter, riser and cover share controlled datums with the tank. Captive hardware and the secondary grate remain in the CAD assembly; the top wordmark clears the lift bores. The included access STEP also contains the pump-out branch. Whole-assembly qualification remains open.

Pump Dock

Hollow guide rails, sliding collars and a carrier frame form the retrieval study. Revised cradle clearances remove the rail clashes found in the assembly audit. Pump selection, hydraulic coupling, tank mounting, retention and lifting loads remain open.

Connect

One mechanical handling family with three different key orientations. Matching mechanical shells clear; mismatched class shells interfere in the geometry test. Contacts, locking, seals and electrical ratings are absent. This is a mechanical class-key study.

Sense Mount

An upright bracket provides instrument apertures and a replaceable metallic saddle. The identity sits on the solid upright, clear of the sensor openings. Exact supplier sensor geometry, clamping and installed location remain open.

Service Kit

A Chalk lid, Graphite body, separate latch envelopes and contacting handle brackets. The wordmark and Fieldline sit below the grip without being obscured. Tool layout, lining, hinge/latch engagement and attachment qualification remain open.

The complete product catalog.

All 48 shop entries are accounted for. Fourteen have a related partial concept render; remaining supplier and custom products need geometry. A housing render does not include an unseen PCB, motor, sensor, treatment medium or filter element.

ProductFamilyModel coverage
Subfield CoreControllersPartial concept
Tank HubControllersPartial concept
Field NodeControllersPartial concept
Equipment adapterControllersPartial concept
Alarm assemblyControllersPartial concept
Exterior power moduleControllersModel pending
Continuous level sensorSensorsModel pending
High-level detectorSensorsModel pending
Low-level detectorSensorsModel pending
Ponding detectorSensorsModel pending
Flow instrumentSensorsModel pending
Pressure instrumentSensorsModel pending
Temperature probeSensorsModel pending
Filter seating indicatorSensorsModel pending
Enclosure monitorSensorsModel pending
Soil observation probeSensorsModel pending
Treatment circulation pumpPumps & treatmentModel pending
Reusable effluent screenPumps & treatmentModel pending
Screen housingPumps & treatmentPartial concept
Treatment media cassettePumps & treatmentPartial concept
Distribution manifoldPumps & treatmentModel pending
Underdrain assemblyPumps & treatmentModel pending
Recycle splitterPumps & treatmentModel pending
Sampling assemblyPumps & treatmentModel pending
Hydraulic service kitPumps & treatmentModel pending
Power and data trunkCables & connectionsModel pending
Device harnessCables & connectionsModel pending
Motor harnessCables & connectionsModel pending
Alarm and protective harnessCables & connectionsModel pending
Keyed connector setCables & connectionsPartial concept
Cable entry and seal kitCables & connectionsModel pending
Field harnessCables & connectionsModel pending
Service diagnostic leadCables & connectionsModel pending
Subfield tank assemblyTank & servicePartial concept
Service access and risersTank & servicePartial concept
Roof seal setTank & serviceModel pending
Penetration interfacesTank & serviceModel pending
Wet service carrierTank & servicePartial concept
Hub carrier and enclosureTank & servicePartial concept
Pump retrieval assemblyTank & servicePartial concept
Level reference setTank & serviceModel pending
Dispersal pumpField equipmentModel pending
Pressure field filterField equipmentPartial concept
Zone and return valvesField equipmentModel pending
Air-management kitField equipmentModel pending
Field piping and headersField equipmentModel pending
Wastewater driplineField equipmentModel pending
Flush-return flow instrumentField equipmentModel pending
Source and revision record

Source: product-design-r1/index-historical.html

Source SHA-256: 17dd953a3105e3bd9b8974c1a3d3b0481f5124ee5587e22d66dbf8c9e3c90339

Geometry and images describe this development revision. Current product ratings and manufacturing release require separate qualification.

Return to the current product.

Explore the retrofit-only platform and its compatibility, installation and service objectives.

Explore the retrofit