Engineering records / Engineering record / BASE-CONTACT-R1
Base Contact R1.
Study overview
Geometry, analysis and remaining engineering work for Base Contact R1.
Retained development study. Dimensions, names and checks belong to this revision—not automatically to the current retrofit system. Manufactured tanks are not offered. No installation instruction, certification or manufacturing release is represented.
The source reasoning
Why this detail was investigated.
The source reasoning
Mapping the nominal post case directly onto the 18 aligned 120 × 80 mm shoes gives a peak nominal average of 6.24 MPa. The corresponding roof pressure is only 0.10144 MPa. This exposes a strong concentration at the floor interface that the current skin/bedding design has not resolved.
Research record
The detail behind
the study.
Source-linked work for this revision. Reported checks describe the stated model or test; physical qualification and applicability to the current retrofit remain separate.
Read the research and limits
Mapping the nominal post case directly onto the 18 aligned 120 × 80 mm shoes gives a peak nominal average of 6.24 MPa. The corresponding roof pressure is only 0.10144 MPa. This exposes a strong concentration at the floor interface that the current skin/bedding design has not resolved.
This is a screening assumption, not a solved base reaction or a soil capacity check. Base-member bending can redistribute forces between shoes; curved contact, local compliance and external bedding can change the pressure distribution. The projected blank area is not a verified effective bearing area. The roof-pressure reference is not a geotechnical allowable.
Do not reduce the shoes or claim that nominal contact completes the load path. A distributed base support and its skin/bedding interaction must be designed. The CSV maps all 18 nominal-case reactions to shoe IDs; the JSON also retains rigid and half-stiffness post cases.
All three cases retain the 661.115 kN roof resultant. No floor strength, settlement, punching, buckling or support-loss acceptance is established by this calculation.
Source and revision record
Source: base-contact-r1/READ-ME.md
Source SHA-256: 77d77c6d3925b69df6ec1597c3e00e30a5f5fd083105d04f4c2f09c4c826bae1
Geometry and images describe this development revision. Current product ratings and manufacturing release require separate qualification.
Return to the current product.
Explore the retrofit system and its compatibility, installation and service objectives.
Explore the retrofit